Power Cylinder

Tsubaki Power Cylinder

Linear actuators (electro-mechanical cylinder) that only need simple electrical wiring


G Series

Tsubaki G Series Power Cylinder

Thrust : 700N to 3.00kN {71.4kgf to 306kgf}

Power cylinder in intermediate thrust zone which can be used with AC power supply. G series can be used across a wide range of applications such as cement, steel, aerobridge.

Model No. designation
LP GC 300 L K 5 V1 LCIJ
Power Cylinder G Series type Thrust Speed Shape of body Nominal
stroke
Voltage Options
GA: Basic type
GB: With torque limiter
GC: With thrust detection mechanism type
070:  700N
100: 1.00kN
150: 1.50kN
300: 3.00kN
L
M
H
U
T: Straight
K: Parallel
2: 200mm
3: 300mm
5: 500mm
V: 400V50Hz, 400V60Hz, 440V60Hz
V1: 380V50Hz
V2: 380V60Hz
V3: 415V50Hz
L: External limit switch for stroke adjustment
C: Clevis fitting
I: I-type end fitting
J: Bellows

The above values are examples of indication. See catalog for more details.

Standard model list
Model Rated thrust Speed (mm/s)
50/60Hz
Stroke (mm)
N {kgf}
LPGA070
LPGB070
LPGC070
700 71.4  L (25/30)
 M (75/90)
 H (100/120)
 U (200/240)
100 - 1200
LPGA100
LPGB100
LPGC100
1.00k 102  L (25/30)
 M (75/90)
 H (100/120)
 U (200/240)
100 - 1200
LPGA150
LPGB150
LPGC150
1.50k 153  L (25/30)
 M (75/90)
 H (100/120)
100 - 1200
LPGA300
LPGB300
LPGC300
3.00k 306  L (25/30)
 M (50/60)
 H (67/80)
100 - 1200
Motor specifications
Model Totally enclosed self cooling type with brake
Output 0.1 - 0.4kW
Number of poles 4 poles
Power supply
Heat resistance class E
Time rating S2 30min.
Protection class Totally enclosed outdoor type (IP55)
Standard use environment
Environment Ambient
temperature
Relative humidity Impact resistance value Installation altitude Atmosphere
Outdoor type -15°C to 40°C 85% or less 1G or less 1000m or lower above sea level Nomally outdoors

T Series

Tsubaki T Series Power Cylinder

Thrust : 2.45kN to 313kN {250kgf to 32000kgf}

This is a power cylinder of a large thrust type which can be used with an AC power supply.

T series can be used across a wide range of applications such as mining, cement, steel, automotive.

Model No. designation
LP TB 1000 L 4 V1 LCIJ
Power Cylinder T Series type Thrust Speed Nominal stroke Voltage Options
TB:Wet slip clutch type
TC:Thrust detection mechanism type
250: 2.45kN {250kgf}
500: 4.90kN {500kgf}
1000: 9.80kN {1000kgf}
S
L
M
H
2: 200mm
3: 300mm
5: 500mm
V: 400V50Hz, 400V60Hz, 440V60Hz
V1: 380V50Hz
V2: 380V60Hz
V3: 415V50Hz
L: Stroke adjusting external LS
C: With clevis fitting
I: I-shaped end fitting
J: With bellows

The above values are examples of indication. See catalog for more details.

Standard model list
Model Rated thrust Speed (mm/s)
50/60Hz
Stroke (mm)
kN {kgf}
LPTB250
LPTC250
2.45 250  S (12.5/15)
 L (25/30)
 M (50/60)
 H (100/120)
200, 300, 400, 500, 600
LPTB500
LPTC500
4.90 500  S (12.5/15)
 L (25/30)
 M (50/60)
 H (100/120)
200, 300, 400, 500, 600, 800
LPTB1000
LPTC1000
9.80
(7.84)
1000
(800)
 S (12.5/15)
 L (25/30)
 M (50/60)
 H (100/120)
200, 300, 400, 500, 600, 800,
*1000 (Rated thrust is 7.84kN)
LPTB2000
LPTC2000
19.6
(15.6)
(12.2)
2000
(1600)
(1250)
 S (12.5/15)
 L (25/30)
 M (50/60)
 H (75/90)
200, 300, 400, 500, 600, 800,
*1000 (Rated thrust is 15.7kN)
*1200 (Rated thrust is 12.3kN)
LPTB4000
LPTC4000
39.2
(33.3)
4000
(3400)
 S (9/11)
 L (25/30)
 M (35/42)
 H (60/72)
200, 300, 400, 500, 600, 800, 1000, 1200
*1500 (Rated thrust is 33.3kN)
LPTB6000
LPTC6000
58.8 6000  S (6.3/7.6)
 L (17.5/21)
 M (25/30)
 H (42/50)
500, 1000, 1500
LPTB8000
LPTC8000
78.4 8000  S (10/12)
 L (20/24)
 M (30/36)
 H (43/52)
500, 1000, 1500
LPTB12000
LPTC12000
117 12000  S (10/12)
 L (18/22)
 M (30/36)
500, 1000, 1500, 2000
LPTB16000
LPTC16000
156 16000  S (14.5/17.5)
 L (20/24)
 M (31/37)
500, 1000, 1500, 2000
LPTB32000
LPTC32000
313 32000  S (10/12)
 L (15/18)
 M (20/24)
500, 1000, 1500, 2000
Standard model list
Model Totally enclosed self cooling type with brake
Output 0.1 - 11kW
Number of poles 4 poles
Voltage
Heat resistance class E
Time rating S2 30min.
Protection class Totally enclosed outdoor type (IP55)
Standard use environment
Environment Ambient
temperature
Relative
humidity
Impact resistance
value
Installation
altitude
Atmosphere
Outdoor type -15°C
to
40°C
85% or less
(no dew condensation)
1G or less 1000m
or lower above
sea level
Normally
outdoors

Catalogs